The UD6348 5000W Low-Frequency Solar Inverter provides robust off-grid AC power for homes, boats, and industrial loads. With pure sine wave output, transformer-based design, and MPPT charging efficiency up to 98%, it ensures stable, reliable, and safe electricity even under high surge conditions.
It includes lithium battery wake-up, BMS protocol support, adjustable grid start voltage, generator auto-start, and multiple communication options, making it ideal for high-demand devices such as water pumps, drills, air conditioners, and heaters.
Key Features
Pure sine wave AC output
High-efficiency MPPT (up to 98%)
Generator auto-start
Adjustable charging & grid start voltages
Low-frequency transformer design
Lithium battery wake-up & automatic restart
BMS protocol support
DC start & automatic self-diagnosis
Overload protection
Lead-acid and lithium battery models
Sustained high-power output for inductive loads
Applications
Off-grid homes and cabins
Marine/boat power systems
Small industrial workshops
High surge/inductive load scenarios
| Model | UD6348 |
| Input voltage | 220V AC/110V AC |
| Input voltage range | 220V:154-264V±3V AC(Normal Mode) 185V-264V±3V AC(UPS Model) 110V:77-132V±3V AC(Normal Mode) 92V-132V±3V AC(UPS Model) |
| Input Frequency | 50/60Hz±5% |
| Out put power | 6300VA 5000W |
| AC model output Voltage | The output voltage under the mains is thesame as the input voltage |
| AC model outout frequency | The output frequency under the mains is the same asthe inputfrequency |
| Battery model output voltage | 220V AV +10% |
| Battery model output frequency | 50Hz or 60Hz+1% |
| Battery model output wave | Pure sine wave |
| Battery type | External lead-acid battery,Gel battery.water battery or Lithium battery |
| Battery voltage | 48V DC |
| Battery charging voltage | 54.8V DC |
| Maximum PV array power | 24V:1600W |
| Solar input voltage range | 12V:PWM 15V-50V DC 24V:PWM 30V-105V DC
|
| Maximum PV Display open Circuit Voltage | 12V:PWM 5OV DC 24V: PWM 105V DC |
| Maximum solar charging current | 60A |
| Maximum AC Charge Current | 50A |
| Transfer time | s10ms(UPS)/s20ms(INV) |
| load peak ratio | (MAX)3:1 |
| Operating temperature | 0°C~40°C |
| Relative temperature | -10°C~90°C no condensation |
| Noise | <45db |